首页 > 产品信息 > Laboman HCLAB EasyAccess英文版检验数据管理软件> 功能一览    
 

 

功能一览( SPECIFICATION )
 
HCLAB EasyAccess Specification功能一览
External Performance
  Connect Analyzers
Hematology Urinalysis Coagulation Bio-Chemistry HbA1c
XE2100 UF100 CA7000 CHEMIX-180 TOSOH 723-G7
XT2000i UF50 CA6000 CHEMIX-800
XT1800i CA1500
SE9000 CA500 Series
SF3000 CA50
KX-21N
KX-21
K4500
Poch100i
XS
Print Connect and use many printers to output the report and relevant report forms at the same time
Display mode XGA Size (1024 x 768 pixel)
Display Content Receive / display the test result and graph ,message, and QC results at the same time
Performance of Database
The test information can store as large as the usable size of hard disk
Introduce Sybase SQL Anywhere database
Connect with LIS Support sending the test result and information which has logged in to LIS
Internal Performance
  Test Information Input offer almost 29 kinds of test and patient's information you can choose to input, and adjust the inputting interface flexibly
  Test Result Display Display the test result and graph, the normal and abnormal message of analyzers
Display the mark of individual test item from analyzers
Display the normal value of the corresponding sex and age bracket automatically according to the patient's age and sex besides the normal value of the test item
Display all the tests results and item trend graph of the same patient within 3 months at most
Input and display the Urinalysis microscope test result
Match the rule of urinalysis automatically, assist the technician in next operation
  Validation Verify the sample and record the corresponding technicians
To verify by batch
  Query Find samples that match a query setting(test date, name,patient type,query condition etc.)
Reports a list of positive results for a specific test that was analyzed during a specific range of time.
22 kinds of query conditions
  QC View current day’s QC results
Specify QC file and QC item parameters
Westgard QC rules are set for automatic QC data checks.
Display the QC chart of recent 20 times automatically (Calculate target values for QC samples and standard deviations based on QC data)
View QC results in a graphical format
Displays and prints monthly QC report and average result or specific result
  Statistics Reports the number samples and test items done during a specific range of time(ordering doctor, ordering clinic, tester, patient type etc.)
Print the report of the number samples and test items
  Print Each analyzers can be appointed special purpose report and printer
Able to do individual or batch printing
Patient report formats can be customized to a limited extent(font/positioning of items)
t test graph and message of analyzers besides test report
The order in which items will be printed in a report can be changed
  Automatically print the patient’s report after the results have been validated
  Item Set properties and reference values of all test items
Set special reference ranges value(age/sex)
Other Performance
  User Administration two user levels management
Communication record view the data communication record with seven days
Database Management Specify the frequency of database backups and compression